Seven key points of circuit board maintenance technology
04Dec
Summer コメント件

Seven key points of circuit board maintenance technology

Seven key points of PCB circuit board maintenance technology


pcb


1Fault CharacteristICs and Maintenance of Capacitance Damage of Industrial Control PCB circuit Board

The failure caused by capacitor damage is the highest in electronic equipment, especially the damage of electrolytic capacitor.

The capacitance is damaged as follows: 1. The capacity becomes SMAller; 2. Total loss of capacity; 3. Electric leakage; 4. Short PCB circuit.

Capacitors play different roles in the PCB circuit, and the faults caused by them have their own characteristics. In the industrial control PCB circuit board, digital PCB circuits account for the vast majority. Capacitors are mostly used as power filter, and less capacitors are used as signal coupling and oscillation PCB circuits. If the electrolytic capacitor used in the switching power supply is damaged, the switching power supply may not vibrate and have no voltage output; Or the output voltage filtering is not good, and the PCB circuit logic is confused due to unstable voltage, which means that the machine is good or bad or cannot be started when it is working. If the capacitor is between the positive and negative poles of the power supply of the digital PCB circuit, the fault performance is the same as above.

This is particularly evident on the computer motherboard. Many computers can not be started or can be started after several years of use. When the chassis is opened, the phenomenon of electrolytic capacitor bulging can often be seen. If the capacitor is removed to measure the capacity, it is found that it is much lower than the actual value.

The life of capacitor is directly related to the ambient temperature. The higher the ambient temperature is, the shorter the life of capacitor is. This rule applies not only to electrolytic capacitors, but also to other capacitors. Therefore, when looking for fault capacitors, we should focus on the capacitors close to the heat source, such as those near the radiator and high-power components. The closer they are, the more likely they are to be damaged.

The user once repaired the power supply of an X-ray flaw detector. The user reported that smoke CAMe out of the power supply. After removing the chassis, he found that a 1000uF/350V large capacitor had oil like flow out. The removed capacity was only dozens of uF. He also found that only this capacitor was closest to the radiator of the rectifier bridge, and the other capacitors far away were intact and normal in capacity. In addition, there is a short PCB circuit in the ceramic capacitor, and it is also found that the capacitor is close to the heating component. Therefore, emphasis should be placed on maintenance and search.

Some capacitors have serious electric leakage, which can even be hot when touched by fingers. Such capacitors must be replaced.

In the maintenance of good and bad faults, except for the possibility of poor contact, most faults are caused by capacitor damage. Therefore, when encountering such faults, we can focus on checking the capacitor. It is often surprising to replace the capacitor (of course, we should also pay attention to the quality of the capacitor, and choose a better brand, such as Ruby, Black Diamond, etc.).

2Characteristics and discrimination of resistance damage

It is often seen that many beginners toss and turn on the resistance when repairing the PCB circuit, which is both disassembLED and welded. In fact, it is much more repaired. As long as you understand the damage characteristics of the resistance, you don't need to spend much time.

Resistance is the most numerous component in electrical equipment, but it is not the component with the highest damage rate. Open PCB circuit is the most common resistance damage. It is rare for the resistance value to become larger, and it is rare for the resistance value to become smaller. Common types include carbon film resistor, metal film resistor, wire wound resistor and fuse resistor.

The first two types of resistors are the most widely used, and their damage characteristics are: first, the damage rate of low resistance (below 100 Ω) and high resistance (above 100k Ω) is high, and the damage rate of intermediate resistance (such as hundreds of ohms to tens of kiloohms) is rare; Second, when the low resistance resistance is damaged, it is often burnt and blackened, which is easy to find, while when the high resistance resistance is damaged, there is little trace.

Wire wound resistance is generally used for large current limiting, and the resistance value is not large. When the cylindrical wire wound resistance is burnt out, some will be blackened, or the surface will be cracked, and some will have no trace. Cement resistance is a kind of wire wound resistance, which may break when burned out, otherwise there is no visible trace. When the fuse resistor is burnt out, some surfaces will blow off a piece of skin, and some have no traces, but they will never be burnt and blackened. According to the above characteristics, we can focus on checking the resistance and quickly find out the damaged resistance.

According to the characteristics listed above, we can first observe whether the low resistance resistance on the PCB circuit board has any signs of burning black. Then, according to the characteristics of most open PCB circuits or large resistance values when the resistance is damaged and the high resistance resistance is easy to be damaged, we can use a multimeter to directly measure the resistance at both ends of the high resistance resistance on the PCB circuit board. If the measured resistance value is larger than the nominal resistance value, The resistance must be damaged (it should be noted that the conclusion can be made only after the resistance value is stable, because there may be a charging and discharging process for parallel capacitor elements in the PCB circuit). If the measured resistance value is smaller than the nominal resistance value, it is generally ignored. In this way, each resistance on the PCB circuit board is measured once. Even if you "kill" 1000 by mistake, you will not miss one.

3A Method for Judging Operational Amplifiers

It is difficult for quite a number of electronic maintainers to judge whether the operational amplifier is good or bad, not only because of their educational level (there are many undergraduates under my command, if they don't teach it, they will certainly not, and it will take a long time to understand it, and there is also a graduate student who specializes in frequency conversion control with his tutor, which is actually the same!). I would like to discuss it with you here and hope it will be helpful to you.

The ideal operational amplifier has the characteristics of "virtual short" and "virtual break", which are very useful for analyzing the operational amplifier PCB circuit of linear application. In order to ensure the linear application, the operational amplifier must work in a closed loop (negative feedback). If there is no negative feedback, the op amp under open-loop amplification becomes a comparator. If you want to judge whether the device is good or bad, you should first distinguish whether the device is used as an amplifier or a comparator in the PCB circuit.

According to the principle of virtual short of the amplifier, if the operational amplifier works normally, the voltages at the same direction input end and the reverse input end must be equal, even if there is a difference, it is mv level. Of course, in some high input impedance PCB circuits, the internal resistance of the multimeter will have some influence on the voltage test, but generally it will not exceed 0.2V. If there is a difference of more than 0.5V, the amplifier will definitely be damaged! (I use FLUKE179 multimeter)

If the device is used as a comparator, the same direction input end and reverse direction input end are allowed to be unequal. If the same direction voltage is greater than the reverse voltage, the output voltage is close to the maximum positive value; If the voltage in the same direction is less than the reverse voltage, the output voltage is close to the maximum value of 0V or negative (depending on dual power supply or single power supply). If the detected voltage does not conform to this rule, the device will be damaged! In this way, you do not need to use the substitution method, and you do not need to remove the chip on the PCB circuit board to judge the quality of the operational amplifier.

4A Trick to Test SMT components with Multimeter

Some SMD components are very small, which makes it inconvenient to test and repair with an ordinary multimeter probe. First, it is easy to cause short PCB circuit. Second, it is inconvenient for the PCB circuit board coated with insulating coating to contact the metal part of the component pin. Here is a SIMple method, which will bring a lot of convenience to the detection.

Take two sewing needles of the smallest size, (deep industrial control maintenance technology column) and close them to the multimeter probe, then take a thin copper wire in a multi strand cable, use the thin copper wire to bind the probe and the sewing needle together, and then solder them firmly. In this way, when measuring SMT components with a stylus with a small tip, there is no risk of short PCB circuit. In addition, the tip can puncture the insulation coating, directly hit key parts, and no longer bother to scratch the film.

5Maintenance Method of PCB circuit Board Common Power Short PCB circuit Fault

During PCB circuit board maintenance, if there is a short PCB circuit in the public power supply, it is often a big problem. Because many devices share the same power supply, each device using this power supply is suspected of short PCB circuit. If there are not many components on the board, the short PCB circuit point can be found by using the "hoe earth" method. If there are too many components, whether the "hoe earth" can hoe to the situation depends on luck. A more effective method is recommended here. With this method, you can get twice the result with half the effort and often find the fault point quickly.

There should be a power supply with adjustable voltage and current. The voltage is 0-30V, and the current is 0-3A. This power supply is inexpensive, about 300 yuan. Adjust the open PCB circuit voltage to the power supply voltage level of the device. First, adjust the current to the minimum. Apply this voltage to the power supply voltage point of the PCB circuit, such as the 5V and 0V terminals of 74 series chips. Slowly increase the current depending on the degree of short PCB circuit. Touch the device with your hand. When you feel that a device is obviously hot, this is often a damaged component. You can take it down for further measurement and confirmation. Of course, during operation, the voltage must not exceed the working voltage of the device, and the connection must not be reversed, otherwise other good devices will be burned.

6A small rubber to solve big problems

More and more boards are used in industrial control, and many boards are inserted into the slot with a golden finger. Due to the harsh industrial site environment, dusty, humid, and corrosive gas environment, the board is prone to poor contact failure. Many friends may solve the problem by replacing the board, but the cost of purchasing the board is very considerable, especially for some imported equipment. In fact, you might as well use an eraser to repeatedly wipe the golden finger, clean up the dirt on the golden finger, and try the machine again. Maybe it will solve the problem! The method is simple and practical.

7Analysis of Electrical Faults of Good and Bad

In terms of probability, the electrical faults of good and bad times generally include the following situations:

1. Poor contact

Poor contact between the board and slot, no connection when the cable is broken, poor contact between the cable plug and terminal block, and faulty soldering of components are all included in this category;

2. Signal interference

For digital PCB circuits, under specific conditions, faults will appear. It is possible that the control system is indeed affected by too much interference, and the parameters of individual components or the overall performance parameters of the PCB circuit board have changed, making the anti-interference ability tend to the critical point, thus causing faults;

3. Poor thermal stability of components

From a large number of maintenance practices, the thermal stability of electrolytic capacitor is poor, followed by other capacitors, triodes, diodes, ICs, resistors, etc;

4. There is moisture and dust on the PCB circuit board.

Moisture and dust will conduct electricity with resistance effect, and the resistance value will change in the process of thermal expansion and cold contraction. This resistance value has a parallel effect with other components. If this effect is strong, the PCB circuit parameters will be changed, causing faults;

5. Software is also a consideration

Many parameters in the PCB circuit are adjusted by software. The margin of some parameters is adjusted too low, which is in the critical range. When the operating condition of the machine meets the reason for the software to judge the failure, the alarm will appear.